    The European COPHES/DEMOCOPHES project
    (2014)
    COPHES/DEMOCOPHES has its origins in the European Environment and Health Action Plan of 2004 to "develop a coherent approach on human biomonitoring (HBM) in EuropeŁ. Within this twin-project it was targeted to collect specimens from 120 mother-child-pairs in each of the 17 participating European countries. These specimens were investigated for six biomarkers (mercury in hair; creatinine, cotinine, cadmium, phthalate metabolites and bisphenol A in urine). The results for mercury in hair are described in a separate paper. Each participating member state was requested to contract laboratories, for capacity building reasons ideally within its borders, carrying out the chemical analyses. To ensure comparability of analytical data a Quality Assurance Unit (QAU) was established which provided the participating laboratories with standard operating procedures (SOP) and with control material. This material was specially prepared from native, non-spiked, pooled urine samples and was tested for homogeneity and stability. Four external quality assessment exercises were carried out. Highly esteemed laboratories from all over the world served as reference laboratories. Web conferences after each external quality assessment exercise functioned as a new and effective tool to improve analytical performance, to build capacity and to educate less experienced laboratories. Of the 38 laboratories participating in the quality assurance exercises 14 laboratories qualified for cadmium, 14 for creatinine, 9 for cotinine, 7 for phthalate metabolites and 5 for bisphenol A in urine. In the last of the four external quality assessment exercises the laboratories that qualified for DEMOCOPHES performed the determinations in urine with relative standard deviations (low/high concentration) of 18.0/2.1% for cotinine, 14.8/5.1% for cadmium, 4.7/3.4% for creatinine. Relative standard deviations for the newly emerging biomarkers were higher, with values between 13.5 and 20.5% for bisphenol A and between 18.9 and 45.3% for the phthalate metabolites. Plausibility control of the HBM results of all participating countries disclosed analytical shortcomings in the determination of Cd when using certain ICP/MS methods. Results were corrected by reanalyses. The COPHES/DEMOCOPHES project for the first time succeeded in performing a harmonized pan-European HBM project. All data raised have to be regarded as utmost reliable according to the highest international state of the art, since highly renowned laboratories functioned as reference laboratories. The procedure described here, that has shown its success, can be used as a blueprint for future transnational, multicentre HBM projects.
    Quelle: http://www.sciencedirect.com/
  • Veröffentlichung
    A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air
    (2016) Pogány, Andrea; Balslev-Harder, David; Braban, Christine F.; Cassidy, Nathan; Ebert, Volker; Ferracci, Valerio; Hieta, Tuomas; Leuenberger, Daiana; Martin, Nicholas, A.; Pascale, Céline; Peltola, Jari; Persijn, Stefan; Tiebe, Carlo; Twigg, Marsailidh M.; Vaittinen, Olavi; van Wijk, Janneke; Niederhauser, Bernhard; Wirtz, Klaus
    The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5-500 nmol mol-1amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project.Quelle: http://iopscience.iop.org
  • Veröffentlichung
    Determination of trace elements in urine by inductively coupled plasma-tandem mass spectrometry - Biomonitoring of adults in the German capital region
    (2021) Schmied, Andy; Kolossa-Gehring, Marike; Murawski, Aline
    A method was developed and validated for multi-element analyses of human urine samples using inductively coupled plasma-tandem mass spectrometry. The combination of a simple sample preparation and the state-of-the-art technique allows high-throughput and lowest limits of quantification up to 1 ng/L. Thereby coefficients of variation ranges from 0.4% (V) to 3.7% (Be), and 0.9% (Cd) to 4.8% (Ni) for intraday and interday precision, respectively. The method's performance is demonstrated by successful participation in international interlaboratory comparison programs as external quality assurance. Moreover, the method was applied for the analysis of first-morning void urine samples of adults (N = 77) living in the German capital region. 15 metals and metalloids (Astotal, Be, Bi, Cd, Co, Cr, In, Mn, Mo, Ni, Pb, Sn, Tl, V, and Zn) were determined. With exception of indium, all elements were found in urine samples above the limit of quantification, demonstrating the suitability to measure the general population's exposure to these metals and metalloids. The method presented here shall be used for analysis of urine samples collected in the upcoming German Environmental Survey, GerES VI, a cross-sectional, population-representative study. Quelle: © Elsevier 2021
  • Veröffentlichung
    Making use of apex predator sample collections: an integrated workflow for quality assured sample processing, analysis and digital sample freezing of archived samples
    (2022) Badry, Alexander; Rüdel, Heinz; Göckener, Bernd; Koschorreck, Jan; Treu, Gabriele
    Using monitoring data from apex predators for chemicals risk assessment can provide important information on bioaccumulating as well as biomagnifying chemicals in food webs. A survey among European institutions involved in chemical risk assessment on their experiences with apex predator data in chemical risk assessment revealed great interest in using such data. However, the respondents indicated that constraints were related to expected high costs, lack of standardisation and harmonised quality criteria for exposure assessment, data access, and regulatory acceptance/application. During the Life APEX project, we demonstrated that European sample collections (i.e. environmental specimen banks (ESBs), research collection (RCs), natural history museums (NHMs)) archive a large variety of biological samples that can be readily used for chemical analysis once appropriate quality assurance/control (QA/QC) measures have been developed and implemented. We therefore issued a second survey on sampling, processing and archiving procedures in European sample collections to derive key quality QA/QC criteria for chemical analysis. The survey revealed great differences in QA/QC measures between ESBs, NHMs and RCs. Whereas basic information such as sampling location, date and biometric data were mostly available across institutions, protocols to accompany the sampling strategy with respect to chemical analysis were only available for ESBs. For RCs, the applied QA/QC measures vary with the respective research question, whereas NHMs are generally less aware of e.g. chemical cross-contamination issues. Based on the survey we derived key indicators for assessing the quality of biota samples that can be easily implemented in online databases. Furthermore, we provide a QA/QC workflow not only for sampling and processing but also for the chemical analysis of biota samples. We focussed on comprehensive analytical techniques such as non-target screening and provided insights into subsequent storage of high-resolution chromatograms in online databases (i.e. digital sample freezing platform) to ultimately support chemicals risk assessment. © 2022 The Authors.
  • Veröffentlichung
    Using environmental monitoring data from apex predators for chemicals management: towards harmonised sampling and processing of archived wildlife samples to increase the regulatory uptake of monitoring data in chemicals management
    (2022) Slobodnik, Jaroslav; Badry, Alexander; Alygizakis, Nikiforos A.; Claßen, Daniela; Koschorreck, Jan; Treu, Gabriele
    Monitoring data from apex predators were key drivers in the development of early chemicals legislations due to the population declines of many species during the twentieth century, which was linked to certain persistent organic pollutants (POPs). Besides triggering the development of global treaties (e.g. the Stockholm Convention), chemical monitoring data from apex predators have been particularly important for identifying compounds with bioaccumulative properties under field conditions. Many apex predators are protected species and only a few environmental specimen banks (ESBs) regularly collect samples as many ESBs were established during the 1980-1990s when apex predators were scarce. Today, many POPs have been banned, which contributed to the recovery of many apex predator populations. As a consequence, apex predator samples are now available in research collections (RCs) and natural history museums (NHMs). These samples can be used for routine analysis as well as for screening studies using novel analytical techniques and advanced data treatment workflows, such as suspect and non-target screening. The LIFE APEX project has demonstrated how these samples can be used in a cost-efficient way to generate data on legacy compounds and contaminants of emerging concern. Furthermore, it has described quality assurance/control measures to ensure high quality and comparable data, with a view to uses in chemicals risk assessment and management. To increase the visibility of available sample collections and monitoring data from apex predators we developed accessible online database systems. Additionally, the acquired high-resolution mass spectrometric data were stored in a digital sample freezing platform that allows retrospective suspect screening in previously analysed samples for substances that may be of concern/under assessment in the future. These databases provide open access to a wide range of chemical data, for use by regulators, researchers, industry and the general public, and contribute to a stronger link between science and policy. © The Author(s) 2022