Publikation:
Tracking down unknown PFAS pollution - The direct TOP assay in spatial monitoring of surface waters in Germany

dc.contributor.authorGöckener, Bernd
dc.contributor.authorBadry, Alexander
dc.contributor.authorFliedner, Annette
dc.contributor.authorWeinfurter, Karlheinz
dc.contributor.authorKoschorreck, Jan
dc.date.accessioned2024-06-16T12:36:03Z
dc.date.available2024-06-16T12:36:03Z
dc.date.issued2023
dc.description.abstractPFAS contamination of surface waters in central Europe was investigated in a spatial monitoring using suspended particulate matter and sediment samples. The samples were collected in 2021 at 171 sampling sites in Germany and at five sites in Dutch waters. All samples were analyzed for 41 different PFAS by target analysis to establish a baseline for these compounds. In addition, a sum parameter approach (direct Total Oxidizable Precursor (dTOP) assay) was used to investigate the PFAS load in the samples more comprehensively. PFAS pollution varied widely between water bodies. Target analysis detected (Sigma)PFAS concentrations between <0.5 and 53.1 (micro)g kg-1 dry weight (dw), while levels of <1.0-337(micro)g kg-1 dw were determined by dTOP assay. Associations were observed for (Sigma)PFSAdTOP and the percentage of urban area in the vicinity of the sampling sites and, less strongly, for distances to industrial sites (i.e. galvanic/paper) and airports. PFAS hotspots were identified by setting the 90th percentile of the data sets for (Sigma)PFAStarget or (Sigma)PFASdTOP as a threshold. Of the 17 hotspots identified by target analysis or dTOP assay, respectively, there were only six overlaps. Thus, 11 highly contaminated sites could not be identified by classical target analysis. The results demonstrate that target analysis captures only a fraction of the actual PFAS load, while unknown precursors remain undetected. Consequently, if only the results of target analysis are considered in assessments, there is a risk that sites heavily polluted with precursors will not be identified delaying mitigation actions and risking prolonged negative impacts on human health and ecosystems. Moreover, effective PFAS management requires establishing a baseline for PFAS using target and sum parameters such as the dTOP assay, and then monitoring this baseline on a regular basis to support emission control and to inform risk management of its effectiveness. © 2023 The Authors.en
dc.format.extent1 Online-Resource (11 pages)
dc.format.mediumonline resource
dc.identifier.doihttps://doi.org/10.60810/openumwelt-2123
dc.identifier.urihttps://openumwelt.de/handle/123456789/1421
dc.language.isoeng
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectGeodaten
dc.subjectSediment
dc.titleTracking down unknown PFAS pollution - The direct TOP assay in spatial monitoring of surface waters in Germany
dc.typeWissenschaftlicher Artikel
dc.type.dcmitext
dc.type.mediumcomputer
dspace.entity.typePublication
local.bibliographicCitation.journalTitleThe Science of the Total Environment
local.bibliographicCitation.originalDOI10.1016/j.scitotenv.2023.165425
local.bibliographicCitation.volume898 (2023)
local.collectionAufsätze
local.contributor.authorId02185377
local.contributor.authorId(DE-588)1210203405
local.contributor.authorId(DE-588)112392970
local.contributor.authorId02054381
local.contributor.authorId02193333
local.identifier.catalogId02502298
local.ingest.leader06406naa a2200000uu 4500
local.jointTitleTRACKING DOWN UNKNOWN PFAS POLLUTION THE DIRECT TOP ASSAY IN SPATIAL MONITORING OF SURFACE WATERS IN GERMANY
local.reviewtrue
local.sourcecatalog
local.source.urihttp://creativecommons.org/licenses/by/4.0/deed.de
local.staffPublicationtrue
relation.isAuthorOfPublicationf797a839-7b1c-450a-ae24-cf4dd70e245d
relation.isAuthorOfPublication474bf2a4-71af-4362-ac51-4bff4bf59981
relation.isAuthorOfPublication.latestForDiscoveryf797a839-7b1c-450a-ae24-cf4dd70e245d
Dateien
Sammlungen