Person:
Chorus, Ingrid

Lade...
Profilbild
E-Mail-Adresse
Geburtsdatum
Forschungsvorhaben
Berufsbeschreibung
Nachname
Chorus
Vorname
Ingrid
Name

Suchergebnisse

Gerade angezeigt 1 - 2 von 2
  • Veröffentlichung
    Combating cyanobacterial proliferation by avoiding or treating inflows with high P load ̶ experiences from eight case studies
    (2015) Abella, Sally E. B.; Chorus, Ingrid; Litt, Arni; Fastner, Jutta; Morabito, Giuseppe; Voeroes, Lajos; Pálffy, Károly; Straile, Dietmar; Kümmerlin, Reiner; Matthews, David; Phillips, M. Geoff
    Increased external nutrient loads of anthropogenic origin, especially those of phosphorus (P), were one of the major causes of eutrophication during the first half of the twentieth century in Europe. They led to deterioration of lake ecosystems, particularly including noxious blooms of (potentially toxic) cyanobacteria. From the 1970-1980s, strategies to decrease the phosphorus loads from sewage were increasingly implemented, among them are the ban of phosphates in detergents, the expansion of sewer systems and improvement in wastewater treatment to remove nutrients. Case studies of eight lakes, whose response to point source reduction of phosphorus was observed over decades, show that a pronounced reduction of the phosphorus load from point sources can be achieved either by the diversion of inflows carrying high loads, by upgraded sewage treatment, or by phosphorus precipitation in the major tributary directly before its inflow into the water body. Outcomes demonstrate that in order to effectively control cyanobacterial blooms, the measures taken need to reduce in-lake concentrations of total phosphorus below 20-50 Ţg L-1, with this threshold varying somewhat between lakes depending in particular on hydromorphological and biological conditions. Whether and when load reduction succeeds in controlling cyanobacteria depends primarily on the load remaining after remediation and on the water residence time.
    Quelle: http://link.springer.com/
  • Veröffentlichung
    Decades needed for ecosystem components to respond to a sharp and drastic phosphorus load reduction
    (2020) Beulker, Camilla; Köhler, Antje; Chorus, Ingrid; Fastner, Jutta
    Lake Tegel is an extreme case of restoration: inflow treatment reduced its main external phosphorus (TP) load 40-fold, sharply focused in time, and low-P water flushed the lake volume ~ 4 times per year. We analysed 35 years of data for the time TP concentrations took to decline from ~ 700 to 20-30 (my)g/l, biota to respond and cyanobacteria to become negligible. The internal load proved of minor relevance. After 10 years, TP reached 35-40 (my)g/l, phytoplankton biomass abruptly declined by 50% and cyanobacteria no longer dominated; yet 10 years later at TP < 20-30 (my)g/l they were below quantifiable levels. 20-25 years after load reduction, the lake was stably mesotrophic, macrophytes had returned down to 6-8 m, and vivianite now forms, binding P insolubly in the sediment. Bottom-up control of phytoplankton through TP proved decisive. Five intermittent years with a higher external P load caused some 're-eutrophication', delaying recovery by 5 years. While some restoration responses required undercutting thresholds, particularly that of phytoplankton biomass to TP, resilience and hysteresis proved irrelevant. Future research needs to focus on the littoral zone, and for predicting time spans for recovery more generally, meta-analyses should address P load reduction in combination with flushing rates. The Author(s) 2020